Kaw Electronics Co,. Limited is supplying HM8-C3-1t-6B zemic load cells HM8-C3-2t-6B HM8C-C3-3t-6B NHS-22t NHS-33tand following products: High precision Load cells, Weighing equipments, Digital personal scales,Kitchen Scales,Body Fat
Scales and electrical weighing systems; RF products, onnectors,interconnect components, connector adaptors, mobile phone amplifier, GSM repeater, 3G repeater, power divider, two-way radio accessories, transceiver antenna, base station antenna, Omni directional fiber glass antenna, RFID Guard Touring System, RFID hand terminal, GPS and Navigation accessories.
Contact person: Brent Xu(sales Manager)
Kaw Electronics Co., Ltd
TEL: 86-755-86640950
Add: HaiDe Mansion, Nanxin Road, Nanshan District, Shenzhen, China. 518052
Features of KHM8C Shear Beam Load Cell :
· Alloy steel IP67 shear beam load cell
· Adhesive sealed
· Suitable for platform weighing, bed weighing, etcetera
· High accuracy, high reliability
Capacity of HM8-C3-1t-6B zemic load cells HM8-C3-2t-6B HM8C-C3-3t-6B NHS-22t NHS-33t:
500kg C3 Shear Beam Load Cell KHM8C
1t C3 Shear Beam Load Cell KHM8C
1.5t C3 Shear Beam Load Cell KHM8C
100t C3
Shear Beam Load Cell KHM8C
Specification of HM8-C3-1t-6B zemic load cells HM8-C3-2t-6B HM8C-C3-3t-6B NHS-22t NHS-33t:
Accuracy class OIML R60 C3
Output sensitivity ( = FS ) mV/V 3.0 ± 0.003
Maximum capacity ( Emax ) kg 0.5, 1, 1.5, 2, 2.5, 3, 5, 101
Maximum number of load cell intervals ( nLC ) 3000
Ratio of minimum LC verification interval Y = Emax / vmin 0.5 - 2.5t: 10000 or 150002 3 and 5t: 7000 10t: 4000
Combined Error %FS ± 0.020
Minimum dead load kg / klb 0
Safe overload of Emax 150 %
Ultimate overload of Emax 300 %
Zero balance of FS < ± 1.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Terminal resistance, input 350 ± 3.5
Terminal resistance, output 351 ± 2
Insulation impedance M ≥5000 ( at 50VDC )
Temperature range, compensated °C -10 ~+40
Temperature range, operating °C -35 ~ +65
Element material Alloy steel
Ingress Protection (according to EN 60529) IP67
Recommended torque on fixation bolts Nm M12: 100 M18: 200 M24: 700
ATEX classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL II C T4
H3-5T-6B
H3-5.0T-6B
H3-25kg
H3-50kg
H3-100kg
H3-150kg
H3-200kg
H3-300kg
H3-250kg
H3-500kg
H3-750kg
H3-1T
H3-1.0T
H3-1.5T
H3-2T
H3-2.0T
H3-2.5T
H3-3T
H3-3.0T
H3-5T
H3-5.0T
H3F-C3-100kg-3B
H3F-C3-250kg-3B
H3F-C3-500kg-3B
H3F-C3-750kg-3B
H3F-C3-1T-6B
H3F-C3-1.0T-6B
H3F-C3-1.5T-6B
H3F-C3-2T-6B
H3F-C3-2.0T-6B
H3F-C3-2.5T-6B
H3F-C3-5T-6BSingle Point Load Cells KB6G,
Single Point Load Cells KL6G,
Single Point Load Cells KL6E,
Single Point Load Cells KL6D,
Single Point Load Cells KL6C,
Single Point Load Cells KB6F,
S-Type Load Cells KH3,
S-Type Load Cells KH3G,
S-Type Load Cells KB3G
HM8-C3-1t-6B zemic load cells HM8-C3-2t-6B HM8C-C3-3t-6B NHS-22t NHS-33t
NHS-A-1t,NHS-A-2.2t,NHS-A-3.3t,NHS-A-4.7t,NHS-A-10t,NHS-A-15t,NHS-A-22t,NHS-A-33t,NHS-A-47t,NHS-A-68t,NHS-A-100t;
NHS-1t,NHS-2.2t,NHS-3.3t,NHS-4.7t,NHS-10t,NHS-15t,NHS-22t,NHS-33t,NHS-47t,NHS-68t,NHS-100tNHS-SS-1t,NHS-SS-2.2t,NHS-SS-3.3t,NHS-SS-4.7t,NHS-SS-10t,NHS-SS-15t,NHS-SS-22t,NHS-SS-33t,NHS-SS-47t,NHS-SS-68t,NHS-SS-100t
NHS-10t,NHS-22t,NHS-33t,NHS-47t,NHS-68t,NHS-100t,NHS-150t